SIELC Introduces a New Type of Mixed-Mode Columns

SIELC Technologies introduces a new type of mixed-mode separation media. By further improving on mixed-mode methodology, a new generation of separation media was developed. This new generation of columns offers a significant step in obtaining a universal platform for all types of small molecule separation. Previous generations of the mixed-mode media suffer from such limitations as restricted use of methanol in the mobile phase, poor peak shape, low efficiency for multi-charged molecules, high buffer concentration requirement and poor retention of non-charged molecules. All these limitations have been overcome with the Newcrom stationary phase.

The new surface chemistry is based on the idea of moving the charged embedded functional groups as far from silica gel surface as possible.

 

This was achieved by attaching a long alkyl chain to the silica gel surface and placing an ion-exchange group at the terminal end of this chain.  As a result, the ion-exchange functional groups have high mobility inside the pores of the solid particles. This eliminates the chelating (trapping) effect observed with multi-charged analytes on a surface of traditional ion-exchangers. The embedded ion-exchange groups in Newcrom behave as ions in a solution, not as ions on a surface. While highly mobile, they can not go beyond the length of the ligand chain.

 

Chromatography related to ion-exchange process thus still takes place. Ions of opposite charge can be retained and separated based on their charge, ion size, and polarization ability.  Also, reverse-phase nature of the stationary phase allows ion separation based on their hydrophobic properties, charge position in the molecular skeleton and isomeric structure of none-charged part of the molecule.

 

Additional benefits of these stationary phases are low concentration of buffer in the mobile phase needed to generate efficient ion-exchange. Some amount of formic acid (HCOOH) in the mobile phase is all that’s required to generate efficient ion-exchange process. For low UV applications, small amount of phosphoric acid (H3PO4) works as an efficient mobile phase ionic modifier. Yet another benefit is very short equilibration time for switching from one buffer to another, while on older ion-exchange columns the equilibration usually takes many column volumes to get stable retention.

Methanol and acetonitrile, as well as any of their combination can be used to change selectivity of the separation

Columns with a new outer design and with a new chemistry inside
Available diameters: 2.1, 3.2, and 4.6 mm
Available length: 50, 100, and 150 mm

Newcrom R1
Newcrom A
Newcrom B
Newcron AH
Newcrom BH

菲羅門
全國服務
熱線:020-22826668 | E-mail:vink@gzflm.com
公司地址:廣東省廣州市天河區天河北路179號尚層國際大廈13層(510620)
Guangzhou FLM Scientific Instrument Co.Ltd
Floor 13,Shangcengguoji Buiding,No.179 Tianhe Bei Lu,Linhe Street,Tianhe District,GuangZhou,510620, China
CopyRight © 2002-2022 廣州菲羅門科學儀器有限公司 版權所有 粵ICP備05059471號 -1
免責聲明 | 聯系我們 |
信用中國  
掃一掃,添加菲羅門公眾號
主站蜘蛛池模板: 股票| 岑巩县| 河南省| 奈曼旗| 延寿县| 望城县| 江油市| 肥东县| 芦山县| 恩施市| 灯塔市| 通化县| 中宁县| 自贡市| 遂溪县| 廊坊市| 黄梅县| 渭源县| 成安县| 陵川县| 沙田区| 营山县| 卢龙县| 西乡县| 望城县| 黄骅市| 应用必备| 岫岩| 广水市| 临潭县| 枣阳市| 襄汾县| 凤凰县| 南皮县| 滦平县| 东乡族自治县| 广水市| 四平市| 永昌县| 申扎县| 台安县|